SALIENT SPECIFICATIONS
INPUT
230V ±10%, 50 Hz, 3f, 5 Wire
OUTPUTS
Heater |
6.3V RMS @ 2.5 A |
Grid (WRT Cathode) |
-190 to -500 V (Beam Off) |
|
+125 to +250V (Beam On) |
Rise/Fall Time |
20 nano secs |
Throughput Delay |
75 nano secs |
Cathode (WRT Helix) |
-10.5 KV |
Collector 1 (WRT Cathode) |
50 % Of Cathode Voltage @ 100 mA |
Collector 2 (WRT Cathode) |
35 % Of Cathode Voltage @ 300 mA |
Helix |
Ground; Current 15 mA |
PROTECTIONS
- 3 Minutes Heater Warm-up
- Helix Over voltage, Over current
- Thermal Overload: TWT & Power Conditioner
- TWT Arcs
- External Overload ETC.
MONITORS
- Status & Fault Outputs
- Helix Voltage & Current
MECHANICAL
- Dimensions : 390 D x 228 W x 191 H mm
- Weight : <15 Kg
- Cooling : Integral Forced Air Cooled
Environmental